Several calcified foci in left pelvis, most probably phleboliths. Woman with end-stage renal disease ESRD undergoing peritoneal dialysis. Referred for ascertaining correct placement of Tenckhoff catheter. This case is not intended to be a personal endorsement or recommendation of this product. Support Radiopaedia and see fewer ads.

Author:Jushura Metaxe
Country:Namibia
Language:English (Spanish)
Genre:Relationship
Published (Last):18 January 2011
Pages:41
PDF File Size:2.16 Mb
ePub File Size:20.45 Mb
ISBN:254-7-50012-899-4
Downloads:64450
Price:Free* [*Free Regsitration Required]
Uploader:Voodoom



During the peritoneal dialysis PD treatment, an access route to the peritoneal cavity is required, which is why a catheter is installed so that the dialysis solution flows during the drainage stage to the outside and, in the infusion stage, the new liquid is introduced into the cavity. In this unit, you will comprehend the importance of the care to the peritoneal dialysis catheter that is used permanently in people with PD replacement therapy, affected by Chronic Renal Failure CRF , with the main purpose of identifying preventive measures, starting from the clinical manifestations such as the signs and symptoms of alarm, for the opportune detection of the alterations or dysfunction of the catheter; also, the most frequent classification of catheters is explained, as well as their placement and the techniques each catheter needs.

Peritoneal Dialysis [image]. Recognize the preventive measures and the care of the peritoneal dialysis catheter, based on the installation techniques and signs and symptoms of alarm, all this for the opportune detection of the alterations or dysfunction of it. The catheter used for the peritoneal dialysis PD is an essential piece to the performance of PD in its different modalities:.

Desliza Izquierda o Derecha. Both modalities of PD are the means by which the dialysis solution is introduced into the peritoneal cavity of the person with Chronic Renal Failure CRF. The use of catheters as a means of access to the peritoneal cavity dates from the creation of the polyvinyl catheter in , with which it was sought to avoid folds and obstructions; however, its placement was difficult.

After various developments, in , Palmer and Quinton present the PD catheter, designed with silicone, with a round tube structure, wide hole and in the distal part numerous holes. This catheter was improved in by Henry Tenckhoff, with the purpose of preventing infections and damage to the same. It is the classic and most used from the market. The rest are variants with modifications in the intraperitoneal, intraparietal or external portion.

This catheter has one or two cushions, although, for chronic dialysis, the second is used. This catheter allows the separation of the parietal and visceral layers of the peritoneum, the number of holes in the distal segment ensures a better infusion and draining.

This catheter has two perpendicular silicone discs in the final section to separate the omentum and the intestine from the holes. It has a deep cuff that presents a Dacron disc; As you can see in the figure, it is designed to minimize leaks and fix the catheter in the right place. Next to this disc, it has a silicone pellet to allow the catheter to trap the peritoneum and the posterior fascia between the disc and the pellet, leaving the cuff or inner dacron inside the rectus abdominis muscle; This is a different method of implantation than is done in the Tenckhoff catheter.

It is similar to the Tenckhoff catheter, but has the same internal fixation as the Toronto catheter; In addition, so that the catheter does not migrate, it has a natural curvature of 45 degrees. Researchers at the University of Missouri designed a v-shaped catheter, called a catheter in a swan neck at an angle of degrees between the two cuffs. This facilitates the direction of the intraperitoneal portion of the catheter towards the pelvis and the external portion, when exiting in a downward direction that, according to some studies, allows the decrease in the number of orifice infections, with respect to the lateral or ascending exit of others.

There are other variations to the Tenckhoff: T. It has perforations that facilitate the passage of the dialysis fluid from the outside to the peritoneal cavity and vice versa. In this portion, most catheters have a radiopaque strip and are totally opaque to X-rays. This intraperitoneal segment is usually straight. It has one or two cuffs; these cause a progressive inflammatory response, which allows the growth of fibrous tissue and granulation in about a month, this favors the fixation of the catheter.

It is believed that it can act as a barrier against bacteria, although it is not known with certainty. It is observed from the exit orifice, which is what we can see once the catheter is placed.

It is where a connector is placed to attach the appropiate extension for the system that is going to be used. The installation of a catheter in the peritoneal cavity is done through various techniques such as percutaneous and surgical.

The latter is the safest, so that nursing care in the postoperative period are essential to start treatment and avoid complications that affect the expected benefits of replacement therapy, such as catheter migration. Said installation guarantees the most precise location and avoids the migration of the catheter in the peritoneal cavity, which becomes an obstacle for the infusion and drainage of the dialysis solution due to the bad placement of the abutment.

Peritonitis can be another complication; however, there is always the possibility of removing the catheter. A mark is made at the previously valued placement site. The abdomen is prepared with aseptic technique; then, the surgical area is anesthetized and the catheter from the insertion site is measured to where the proximal dacron device is located; at the end, an incision of approximately two centimeters is made.

It is a surgical technique that uses two 12 mm ports to place the DP catheter; It is performed by means of a Guyon guide or atraumatic tip, where the catheter is placed once lubricated, thus obtaining a rigid catheter. Using a minimal periumbilical laparotomy, the tip of the catheter is placed in the bottom of the Douglas pouch and the Guyon guide is removed. The appropriate placement of the catheter should be checked visually, and then the two trocars should be removed, externalizing the catheter, through the hole where the left trocar was removed.

For this procedure, the patient is required to be in the supine position, face up, under local sedation and with the possibility of using intravenous sedation. It begins with a transumbumbilical incision, either on the right or left side of the patient, measuring between three and four centimeters, dissecting the subcutaneous cellular tissue, reaching the aponeurosis.

At the end of the catheter, it must be externalized through the paramedian contraincision, which is three or four centimeters away from the original incision, which forms a tunnel that leaves the second dacron or bearing in the subcutaneous area and without fixation. In order to detect any alteration, the catheter should be followed up permanently, once installed.

In general terms, complications are identified when dialysis treatment begins, so the nursing assessment is substantial to keep the system closed and provide care at the catheter exit site. In open surgery, a range of between two to six weeks of healing is considered; therefore, it is important to take care and follow up the scarring of the exit site and detect complications and start with peritoneal dialysis.

It should be mentioned that the catheter can remain in a cavity for two to five years; however, on average, their stay is two in our national context, since it depends on the care received.

To start the PD, the catheter is connected to a metallic connector and, later, to a transfer line, which must be changed every six months by the nursing staff, using aseptic technique. The PD system is permanently closed by a cap that is replaced by a new one every time dialysis is performed.

The Tenckhoff peritoneal catheter is placed deep in the peritoneal cavity according to the scheme, suturing the abdominal musculature, in order to fix it and avoid migration in chronic PD. Mesenterium [image]. Among the signs and symptoms that may arise due to the installation, permanence or removal of the catheter, it is very important to recognize those that alert us to a possible infection. In most cases, it is usually a reason to stop the treatment and remove the catheter.

Some of the important signs and symptoms are:. If the person reports or notes any of these symptoms, it is likely that an infection is developing, of which it is important to communicate to the trained nursing staff.

Care for the catheter in the installation. Some essential points for the care of the catheter and its insertion site, that help us prevent complications and allow us to keep the catheter route accessible, are:.

The main complications are related to catheter settlement, fluid leakage and infections. The Tenckhoff catheter has been the means of access to PD substitution treatment; however, there is a possibility that complications associated with the catheter may occur, such as:. Due to this situation, catheter proposals have been generated, such as the pig tail, which fulfill the following intentions:.

The catheter for peritoneal dialysis PD needs a correct installation and placement to avoid complications to the patient during the treatment. According to the classification and composition of the DP catheter, relate each part with the corresponding description by dragging the correct option to the blank space in the sentences.

When you finish, you can recognize the composition of the catheter for PD and, thus, detect any possible dysfunction. There is a diversity of situations that you will face if the necessary care is not taken to the catheter, from its installation to the verification of its procedure. Carefully review the following case, so that you can detect in a timely manner the signs and symptoms that may appear during a treatment.

Information sources. Castro, J. Experiencia mexicana. Smith, T. Peritoneal dialysis and home dialysis therapies. Nurse key. Fastest nurse insight engine. How to quote. Peritoneal Dialysis Catheter. Unidades de Apoyo para el Aprendizaje. Retrieved on date from link. Definition and Classification The catheter used for the peritoneal dialysis PD is an essential piece to the performance of PD in its different modalities: Click on the arrows to see the two modalities of DP.

Tenckhoff Curl cat Toronto Western T. Catheter Missouri Catheter —Swan neck— It is the classic and most used from the market. Installation and placement The catheter consists of three well-defined segments.

Click on each portion of the Tenckhoff catheter to identify its characteristics:. Intraperitoneal portion Intraparietal Portion External Portion. Intraperitoneal portion It has perforations that facilitate the passage of the dialysis fluid from the outside to the peritoneal cavity and vice versa.

Intraparietal Portion It has one or two cuffs; these cause a progressive inflammatory response, which allows the growth of fibrous tissue and granulation in about a month, this favors the fixation of the catheter.

External Portion It is observed from the exit orifice, which is what we can see once the catheter is placed. Desliza Izquierda o Derecha Seldinger or percutaneous insertion A mark is made at the previously valued placement site.

Laparoscopic It is a surgical technique that uses two 12 mm ports to place the DP catheter; It is performed by means of a Guyon guide or atraumatic tip, where the catheter is placed once lubricated, thus obtaining a rigid catheter. Surgical For this procedure, the patient is required to be in the supine position, face up, under local sedation and with the possibility of using intravenous sedation.

Relationship of alarm signs and symptoms. Some of the important signs and symptoms are: If the person reports or notes any of these symptoms, it is likely that an infection is developing, of which it is important to communicate to the trained nursing staff.

Characteristics of the insertion site. Therapeutic care and preventive measures. Complications associated with the catheter. The Tenckhoff catheter has been the means of access to PD substitution treatment; however, there is a possibility that complications associated with the catheter may occur, such as: Due to this situation, catheter proposals have been generated, such as the pig tail, which fulfill the following intentions:.

The composition of the catheter for PD. Clinical case There is a diversity of situations that you will face if the necessary care is not taken to the catheter, from its installation to the verification of its procedure. After reviewing the case click on the correct answer for each question.