The P is a simple, economical, electrically operated lubrication pump unit. It can provide directly a maximum of two individual lubrication points with lubricant or be connected to progressive metering devices. An integrated control board is available to set pause and lubrication time. Developed for fluid grease and grease, the P features an optimized housing shape and reservoir suitable for food processing applications. Change Location: Group.

Author:Nale Fenrijas
Country:Reunion
Language:English (Spanish)
Genre:Literature
Published (Last):17 August 2012
Pages:407
PDF File Size:13.41 Mb
ePub File Size:13.43 Mb
ISBN:820-5-96517-121-7
Downloads:72927
Price:Free* [*Free Regsitration Required]
Uploader:Vudogar



Quick Links. Download this manual. User Manual. Installation and Operation Instructions. Lubrication System QLS Table of Contents. Lubrication systems Lincoln User Manual gallon fuel caddy 32 pages. Page 2 All rights reserved.

Subject to modifications without prior notification. KG, is the user's re- The signal words give the seriousness of danger if the follow- sponsibility. KG will gladly assist you ing text is not observed: with any questions pertaining to the installation.

Page 5: Safety Instructions Owner Manual will be regarded as misuse. When executing any maintenance or If the QLS is used or operated in a different manner other repair works on the QLS , ensure than specified, any claim for warranty or liability will be null absolute cleanliness. Observe the operating temperatures must operate with mounted pressure relief valve, only. Drilling template and mounting bolts are included in A single output is the lubricant quantity fed to the lube point the package.

Page 8: Direct Internal Feedback Feature User Manual Installation and Operation Instructions Installation Instructions, continuation Direct internal feedback feature All pumps with back- mounted SSV divider block have the capability to feed back unused lubricant internally from closed outlets directly to the reservoir see R fig. This procedure will start automatically, if outlet port 2 is plugged with a closure plug.

Page 9: Lubrication Points User Manual Installation and Operation Instructions Installation Instructions, continuation Lubrication Points Installing Quicklinc fittings into lube points Remove hydraulic lube fittings from lube points and install appropriate Quicklinc fittings into the bore holes of the lube points.

NOTE Avoid sharp bends of the plastic tubing and the moving parts of the machine that could damage the lubrication lines. Page Description The function of the pump is independent of the SSV divider block's mounting posi- tion.

Page 13 b04 Fig. Page Selection Guide External divider block Back vertical order Bottom horizontal order Do not install the pump in areas exposed to shock. Operating Voltage 12 VDC Page Vac External divider block Operating Voltage VAC with control p.

The pressure relief valve limits the pressure build-up in the QLS It opens at an overpressure of bar psi. If the pressure relief valve is actuated, this indicates that the system is malfunctioning.

Page Display Mode User Manual Installation and Operation Instructions Setting and Operation, continuation Three possible modes of operation and settings can be se- Display mode lected on the keypad: Operating mode Programming mode Display Mode In the display mode the user receives information on functions and malfunctions. Page Operating Mode User Manual Installation and Operation Instructions Setting and Operation, continuation Display Mode, continuation To acknowledge malfunctions The flashing display is changed into a continuous light by pressing the button acknowledging.

However, check regu- attention should be paid to cleanliness. Let the QLS run and fill the empty reservoir through When filling the reservoir by means of the filler fitting pos. Cause: Remedy: Proximity switch is not dampened, i. Check does not move within the switching range of the proximity whether the control pin moves centrically over the switch- switch, or the distance between the control pin and the Page 33 Check pressure relief valve page 15, fig.

Replace it, if necessary. Page Electrical Data User Manual Installation and Operation Instructions Troubleshooting, continuation Fault: Blockage in the downstream progressive system, continuation Cause: Remedy: Divider valve is blocked Replace the divider block or clean it as follows: - Remove all threaded tube fittings. Before starting, make sure that the Connect the electrical wires according to the following electrical supply is off.

The device may electrical connecting diagrams see page 36 to Designation Part no. Part Part Reservoir Quarter-turn type plug see page 45, fig. Page 45 Explosion view with back mounted SSV divider block vertical outlets with quarter-turn type plug b04 Fig. Page 46 Service Parts, continuation Explosion view with back mounted SSV divider block vertical outlets with square-type plug b03 Fig.

Print page 1 Print document 48 pages. Cancel Delete. Sign In OR. Don't have an account? Sign up! Restore password. Upload from disk. Upload from URL.

KATHREIN EXR 552 PDF

Lincoln QLS 401 Manuals

Quick Links. Download this manual. User Manual. Installation and Operation Instructions. Lubrication System QLS Table of Contents.

COURS DE RECHERCHE OPERATIONNELLE GRATUIT PDF

Lincoln QLS 401 User Manual

The QLS is a complete lubrication system that includes all necessary monitoring and control functions. All components including an internal pressure relief valve are part of the complete package. The comprehensive list of standard features is a remarkable characteristic of the QLS The integrated, all-in-one system concept reduces installation time and costs. The QLS is designed for all industrial and mobile applications. Up to 18 lubrication points can reliably be supplied directly from the pump and monitored at an affordable price.