DS7400XI BOSCH PDF

Quick Links. Download this manual. Turning Off disarming your System. For additional information on operating this system, consult the DSXi Ver. Keypad Quick Reference Guide. Commands for other System Features.

Author:Kigashura Nikozshura
Country:Burma
Language:English (Spanish)
Genre:Marketing
Published (Last):25 October 2006
Pages:345
PDF File Size:9.99 Mb
ePub File Size:5.34 Mb
ISBN:310-9-51195-241-5
Downloads:97311
Price:Free* [*Free Regsitration Required]
Uploader:Kigakus



Page Count: Reference Guide. Force Arming Enter an arming command. T urning Off disarming your System. Keyp ad Quick Reference Guide. Sta tu s. Ready T o Arm. DSXi Ver. Keypad Quick Reference Guide Load Currents Address Program Address Programming Addresses Program Addresses Programming: Program Address Listed Systems L Sy ste m C onf ig urations Communicator T ransmitter with local bell.

Digital Alarm Communicator T ransmitter with. The standard enclosure is manufactured from 20 Ga. A keyed lock is included, and this enclo-. The total current output capacity for all auxiliary devices,. The following ratings are maximum values. The total combined output cannot exceed the max. Listed Auxiliary power: 12 VDC, 1.

Can be. Shorts to Aux. Connect device to Aux. Up to total zones with expansion modules. No more than 2 keypads 22 AWG or 3 keyp ads A WG are recommended on any foot m run. Shared cable is not recommended for keypad, multiplex,. Will report to two phone numbers with full single, double and back-.

The system has the capacity for 8 independent partitions. One p ar-. The DSXi system allows up to 90 individual users. Each user. MOVs and spark gaps provide protection from lightning surges and. Fire circuit will work with 2- or 4-wire detectors and has optional. Up to feet m per system. Do not use twisted pair or sheilded cable for.

Load Currents. Curre nt By Output : Not to exceed t he max. Ins tal lati ons. Applicatio ns. Programmable Output 2. Load Cu rrents. Recha rgeab le. Battery S ize Max. St andb y. Stan dby.

St andby. Devi ce Quantity S ta ndby C urrent. Per D evi ce T otal Standby Cur rent. Quanti ty x S tandby. Current Per Device. Alarm Curren t. Quantity x Alarm. Grand T ota l Grand T ot al. T ot al of all outp uts cann ot ex ceed mA. DS - 8 In put Di rect. DS7 - Mult ip lex Exp ans ion. DS - 8 Inp ut R emo te. Contr ol Pa nel. DS - Sin gle Lin e Mo nitor. Bells, Ho rns, etc.

Oth er sensor s. The DS module. It provides two supervised The DS provides a two-wire multiplex bus for the. It also supplies. The DS Open or Normally Closed contact s. It reports their. It will support Can not be used. The DS provides a means of expanding the. Each zone can support up to twenty 2-wire smoke. The DS provides two two-wire multiplex buses. It also. LEDs representing the first 8 zones of the system. A built in sounder is used as an interior. It displays information on various control.

A built-in sounder is used as an. Alpha Keypad will provide a ten 10 second access. The relay will energize at the keypad if the user has a. The output will change only if the user has access to. The DS is intended as a replacement for. Occupies 1.

It reports their status to the control panel as. It occupies one multiplex zone. Requires a. It occupies two multiplex zones. Normally Closed contacts. It reports their status to the. The DS provides a means of monitoring bells. Fault Output to be connected to the control panel. The DS provides a means of monitoring a single. When a fault is detected,.

APC AR3150 PDF

Bosch DS7400Xi Manuals

Free shipping. Skip to main content. Email to friends Share on Facebook - opens in a new window or tab Share on Twitter - opens in a new window or tab Share on Pinterest - opens in a new window or tab. Add to Watchlist. People who viewed this item also viewed. Picture Information. Mouse over to Zoom - Click to enlarge.

MAGE THE ASCENSION STORYTELLERS HANDBOOK PDF

Original Genuine DS7400XI-CHIBOSCH Bosch Bus Alarm Host Bosch Anti-Theft Alarm Host Bosch

.

Related Articles